Sage espresso machine error codes
An error code tells you which part or function the machine has detected a fault in. Most codes come down to a single part: a sensor, a thermal fuse, a pump or a heating element. Pick your model and type the code.
Tip: Switch the machine off at the wall, wait a couple of minutes and turn it back on. If the code comes back, the machine needs a repair. Put the code in your enquiry so we know where to start.
Free, no-obligation assessmentYou say yes before we touch it
Ready in 3–7 daysOften faster
6-month warrantyOn the repair
Drop off in ØsterbroPickup by arrangement
Dual Boiler (SES920/BES920)
The code shows on the display when the fault happens.
| Code | What the machine is reporting |
|---|---|
00 | Steam boiler sensor not responding (open circuit) |
01 | Short circuit in the steam boiler sensor |
02 | Coffee boiler sensor not responding |
03 | Short circuit in the coffee boiler sensor |
04 | Group head sensor not responding |
05 | Short circuit in the group head sensor |
06 | No water reaching the steam boiler |
07 | Too much water in the steam boiler (overflow) |
08 | Water is not flowing properly to the coffee boiler |
09 | No water in the coffee boiler at startup |
10 | The coffee boiler has become too hot |
11 | The steam boiler has become too hot |
12 | The group head has become too hot |
Oracle (SES980/BES980)
The code shows as “Error” and a number on the display.
| Code | What the machine is reporting |
|---|---|
1 | Steam boiler sensor not responding at startup |
2 | Steam boiler sensor lost during use |
3 | Short circuit in the steam boiler sensor at startup |
4 | Short circuit in the steam boiler sensor during use |
5 | Coffee boiler sensor not responding at startup |
6 | Coffee boiler sensor lost during use |
7 | Short circuit in the coffee boiler sensor at startup |
8 | Short circuit in the coffee boiler sensor during use |
9 | Group head sensor not responding at startup |
10 | Group head sensor lost during use |
11 | Short circuit in the group head sensor at startup |
12 | Short circuit in the group head sensor during use |
13 | Steam wand sensor not responding at startup |
14 | Steam wand sensor lost during use |
15 | Short circuit in the steam wand sensor at startup |
16 | Short circuit in the steam wand sensor during use |
17 | The coffee boiler is not heating as it should |
18 | The steam boiler is not heating as it should |
19 | The group head is not heating as it should |
20 | Water level or pump feeding the steam boiler is playing up |
21 | The steam boiler water level probes disagree |
22 | No signal from the flow meter at startup |
23 | No signal from the flow meter while brewing |
24 | Fault on the coffee boiler water level probe |
25 | The coffee boiler has become too hot |
26 | The steam boiler has become too hot |
27 | The group head has become too hot |
28 | The control boards cannot communicate |
29 | The grinder motor has overheated |
30 | The grinder did not finish in time |
31 | The tamper did not finish in time |
32 | The steam boiler is leaking or not refilling |
Oracle Touch (SES990/BES990)
The code shows as ER and a number on the touchscreen.
| Code | What the machine is reporting |
|---|---|
ER01 | Steam boiler sensor not responding at startup |
ER02 | Steam boiler sensor lost during use |
ER03 | Short circuit in the steam boiler sensor at startup |
ER04 | Short circuit in the steam boiler sensor during use |
ER05 | Coffee boiler sensor not responding at startup |
ER06 | Coffee boiler sensor lost during use |
ER07 | Short circuit in the coffee boiler sensor at startup |
ER08 | Short circuit in the coffee boiler sensor during use |
ER09 | Group head sensor not responding at startup |
ER10 | Group head sensor lost during use |
ER11 | Short circuit in the group head sensor at startup |
ER12 | Short circuit in the group head sensor during use |
ER13 | Steam wand sensor not responding at startup |
ER14 | Steam wand sensor lost during use |
ER15 | Short circuit in the steam wand sensor at startup |
ER16 | Short circuit in the steam wand sensor during use |
ER17 | The coffee boiler is not heating as it should |
ER18 | The steam boiler is not heating as it should |
ER19 | The group head is not heating as it should |
ER20 | Water level or pump feeding the steam boiler is playing up |
ER21 | The steam boiler water level probes disagree |
ER22 | No signal from the flow meter at startup |
ER23 | No signal from the flow meter while brewing |
ER24 | Fault on the coffee boiler water level probe |
ER25 | The coffee boiler has become too hot |
ER26 | The steam boiler has become too hot |
ER27 | The group head has become too hot |
ER28 | The control boards cannot communicate |
ER29 | The grinder motor has overheated |
ER30 | The grinder did not finish in time |
ER31 | The tamper did not finish in time |
ER32 | The steam boiler is leaking or not refilling |
Barista Touch (SES880/BES880) and Touch Impress (SES881/BES881)
The code shows as ER and a number on the screen.
| Code | What the machine is reporting |
|---|---|
ER01 | Heater sensor not responding at startup |
ER02 | Heater sensor lost during use |
ER03 | Short circuit in the heater sensor at startup |
ER04 | Short circuit in the heater sensor during use |
ER05 | Milk jug sensor not responding at startup |
ER06 | Milk jug sensor lost during use |
ER07 | Short circuit in the milk jug sensor at startup |
ER08 | Short circuit in the milk jug sensor during use |
ER09 | In-line water sensor not responding at startup |
ER10 | In-line water sensor lost during use |
ER11 | Short circuit in the in-line sensor at startup |
ER12 | Short circuit in the in-line sensor during use |
ER13 | The flow meter is counting wrongly at startup |
ER14 | The flow meter is counting wrongly during use |
ER15 | The electronics cannot communicate internally |
ER16 | The grinder motor shut down because of heat |
ER17 | The grinder did not finish in time |
ER18 | The safety circuit tripped on an electrical fault |
Oracle Jet (SES985/BES985)
The code shows as E and a number on the screen.
| Code | What the machine is reporting |
|---|---|
E1 | Heater sensor is open circuit |
E2 | Short circuit in the heater sensor |
E3 | Steam wand sensor is open circuit |
E4 | Short circuit in the steam wand sensor |
E5 | Group head sensor is open circuit |
E6 | Short circuit in the group head sensor |
E7 | The group head is not reaching temperature, typically a blown thermal fuse |
E8 | The flow meter reads wrongly while the machine primes |
E9 | The safety circuit tripped during heating |
E10 | The grinder motor has overheated or is not turning |
E11 | The grinder is jammed and drawing too much current |
E12 | The grinder speed sensor is not reporting normal running |
E13 | The grinder did not finish in time |
E14 | No signal from the pressure sensor while steaming |
E15 | Fault in the power control on the board |
E16 | The steam wand is blocked, or the pressure is abnormal |
E17 | The auger motor is drawing no current |
E18 | The auger motor is drawing too much current, typically a jam |
E19 | The residual current protection has tripped several times |
Questions and answers
Can I clear an error code myself?
Switch the machine off at the wall, wait a couple of minutes and turn it back on. If the code comes back, the machine needs a repair. Put the code in your enquiry so we know where to start.
Does an error code mean the machine is finished?
No. Most codes point at a single part: a sensor, a thermal fuse, a pump or a heating element. Those can be replaced individually.
What does it cost to fix an error code?
It depends which part has failed. A sensor or a fuse sits at the low end, a pump, a boiler or a control board at the high end. You get the price before we start.
What should I write in my enquiry?
Write the code exactly as it appears on the screen, and what the machine was doing just before. That usually tells us a lot before the machine arrives.